iProject

DESIGN AND CONSTRUCTION OF AN INDUCTION COIL

📄 Project Material📋 50 pages📚 Chapters 1–5💾 MS-Word & PDF

Chapters 1–5  |  ₦5,000

Get Complete Project Material Now

ABSTRACT

The write-up details the design and construction of an Induction coil which was capable of producing a high voltage in the secondary winding so as to produce a spark between the adjustable terminals of the secondary winding. The manual method of winding a coil was used to produce the primary and the secondary coil. All other necessary connections were made with respect to the circuit diagram. When a current is applied to the device, a high voltage was induced in the secondary coil through electromagnetic induction in the primary coil. As a result of this high voltage induced in the secondary coil, an electric spark was produced between the terminals of the secondary coil. This valuable device can be applied in the radio transmission station, hospitals, automobiles, labouratories, etc.

 


CHAPTER ONE

 

1.0      INTRODUCTION:

A type of transformer that changes a low voltage direct current to a high voltage alternating current which produces an electric spark is known asINDUCTION COIL (Abbott, 1963).

 

1.1   BACKGROUND OF THE STUDY

When Michael Faraday and Joseph Henry independently discovered the electric induction and its principles back in 1831, they started a chain of events that led to the generation of alternating current electricity without which modern technology could not function. They built upon a discovery made by Hans Christian Oersted in 1820. Oersted found out that electric current flowing through a wire created a magnetic field. This was the first discovery linking electricity and magnet, and it galvanized scientists into a frenzy of research.

 

Faraday and Henry coupled with other few scientists followed the path of research and discovered that moving a magnet through a closed coil of winding did indeed “induce” the flow of an electric current in the wire. Initially, electric induction was a scientific curiosity, the direct current battery which had been invented by Allesandro Volta in 1800, had captured the interest of most of the researchers. It was until later in the 19th century that induction coils became of interest and that was due to the work of several individuals, such as French physists called Armand Hippolyte, Lious Fizeau and A. Apps who improved coil performance. 

 

The induction coil uses the principle of electromagnetism. It is a corollary of Faraday’s law, together with Ampere’s law and Ohm’s law giving rise to the Lenz’s law. The EMF induced in an electric circuit always act in such a direction that the current it drives around the circuit opposes the change in magnetic flux which produces the EMF.

 

The induction coil does not only create an electric field or magnetic field, it also transforms the direct current which is usually of low voltage to high voltage. The induction coils were being used to create electrical discharges in gases at low pressure leading to the discovery of x-rays and real medical breakthroughs. It is often used in automotive ignition systems. Its principle is such that when a direct current is passed through the primary coil, a magnetic field is created which cause an EMF of a very high voltage to be induced in the secondary coil.  The high voltage causes a spark to be produced between the two terminals of the secondary winding.

 

Due to this spark produced across the gap between the two terminals of the secondary winding, the induction coil was also known as the SPARK COIL. The size of the induction coil is determined by the length of spark it could produce (Albert, 1998).

 

1.2   SIGNIFICANCE OF THE STUDY

The study on the construction of an induction coil is significant in automobiles and linear engines. It is used in car ignition to produce a spark at the plug which is used to start car engines.

It is also seen in operation of some medical equipment. The induction coil produces a spark between the terminals of the secondary coil. This spark creates an electrical discharge in gases at low pressure which lead to the discovery of x-rays and in provision of real medical breakthrough (Breithaupt, (2000).

 

1.3      AIMS OF THE STUDY

The principle aim of this project is to construct an induction coil, which is capable of inducing 2500volts on the secondary coil which would produce an electric spark at the adjustable gap between the two terminals of the secondary winding as a result of the very high voltage in it when a current is passed through the device.

 

 

1.4      STATEMENT OF THE RESEARCH PROBLEM

The beginning of every task is always difficult. The fear of embarking on the project construction was a great challenge and a mantle of discouragement.

 

The material and all other components that was used in the construction was not common because the device itself is not common. As a result of this, sourcing for the materials and components was difficult. We had to visit different markets to get them complete.

 

The project is a great work and requires money to carry out the construction. Money has been scare and scarcity has been one of its characteristics. The scarcity of fund to finance the project was a big and challenging problem to overcome.

 

The unavailability of important books and the non easy access to the internet services made the search of information and knowledge needed for the project construction to be delayed. The challenge of moving outside the usual environment in search of information coupled with the waste of time and stress was quiet an intricate assignment.

 

In the packaging of the construction, we found it a bit difficult to source-out for the best and most suitable material for the packaging of the project work.

 

1.5   LIMITATIONS OF STUDY

It is bulky because the winding was done manually.

 

 

 

This Project is for You If:

Yes, This Is My Situation — Send Me the Complete Material

Here's everything you get with the complete project package:

✔Chapters 1–5 (Word & PDF)
✔Abstract & Table of Contents
✔References, Citation & Bibliography
✔Fully Editable Microsoft Word Format
✔Original, Plagiarism-Free Content
✔Delivery Within 24 Hours
Complete package —₦10,000₦5,000
Price may return to ₦10,000 at any time.

See Our Conversations With Students on WhatsApp

Students sharing their experience after using our service

Urgent delivery confirmed
Urgent delivery confirmed
Payment received and project delivered
Payment received and project delivered
Quality work and a repeat order
Quality work and a repeat order
Returning customer appreciation
Returning customer appreciation
Customer appreciation
Customer appreciation
I’ve Seen Enough — Get Me This Project Material

What Other Students Are Saying

“The process was actually fine and I got my project quickly. The only thing I didn't really like was that I would have preferred they sent it via WhatsApp instead of email, because email took a bit of checking on my side. But once I got it, everything was already complete and I just edited small parts before submitting.”
Zina
Kenpoly
“My supervisor rejected my Chapter 1 and 2 and I was honestly lost. I got a material here and it already had everything arranged properly. I just adjusted it to my topic and resubmitted. The difference was clear immediately.”
Favour
Nekede
“My supervisor almost finished me 😭 He rejected everything and said I didn't understand basics. I downloaded something here, used it to restructure my work, and resubmitted. That was how I escaped serious stress.”
Nnamdi
Absu

Can't find what you're looking for?

Search thousands of project topics across every department.

Related Project Materials

See More Science Lab Technology Final Year Research Project Topics & Materials »

🏷 Tags:Induction coilDesign of induction coilConstruction of induction coilRelevance of induction coilEffectiveness of induction coil

Frequently Asked Questions

Is this project original and plagiarism-free?
Yes. All project materials on iProject are original, well-researched, and crafted to be plagiarism-free. They are intended as academic guides and reference materials.
What format will I receive the material in?
You will receive the complete project in both Microsoft Word (.docx) and PDF formats, making it easy to edit and submit.
How soon will I get it after payment?
Once payment is confirmed, the material is delivered within 24 hours to the email address supplied at checkout.
Can I edit the content to fit my own case study?
Absolutely. The Word format is fully editable, allowing you to modify the content, swap out case studies, and adapt the material to your specific research context.
All My Questions Are Answered — Download the Complete Project
Message us